Skip to main content
Schneider Electric SR3B102BD

Schneider Zelio Logic SR3B102BD Smart Relay, 6 DI/4 AI/4 TO

MPN SR3B102BD
Active

Schneider Electric Zelio Logic smart relay, SR3B102BD, with 6 discrete inputs 24V DC, 4 analog inputs (0-10V/0-24V), 4 transistor outputs 24V DC 0.5...0.625 A, integrated clock, program memory check on each power-up.

$77.47 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

SR3B102BD specifications
ParameterValue
Temperature probe typeNTC 10k 77 °F (25 °C) NTC 1000k 77 °F (25 °C) KTY81 210/220/221/222/250 Pt 500
Main product or component typeModular smart relay
Voltage24 V transistor output
Sensing distance10 m between stations, with screened cable (sensor not isolated) analogue input circuit
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max40 °C
Temp operating min-20 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61131-2
Backup time10 years 77 °F (25 °C)
I/O channels4 transistor
Input impedance12 kOhm IB...IG used as analogue input circuit 12 kOhm IB...IG used as discrete input circuit 7.4 kOhm I1...IA and IH...IR discrete input circuit
Analogue input range0–10 V

Product details

Integrator's note – I/O map and supply limits

The SR3B102BD is a Zelio Logic smart relay with six discrete inputs (IEC 61131-2 Type 1, 24 V DC, 4 mA sink), four analog inputs (0–10 V or 0–24 V common-mode, 12 kΩ impedance), and four transistor outputs rated 24 V DC / 0.5–0.625 A each. Supply voltage range is 19.2–30 V DC; the module draws 50 mA without extension, up to 160 mA with expansions. The on-board clock and automatic program memory check on every power-up are enabled by default — no battery required for time-stamped logic, though a backup of 10 years at 25 °C keeps the clock running through extended power loss.

Mounting & field connection

DIN-rail mount, torque terminal screws to 0.5 N·m. Discrete inputs accept 3-wire PNP proximity sensors; analog inputs operate over a 10 m screened cable distance between stations. Transistor outputs include overload and overvoltage protection. Cycle time ranges 6–90 ms depending on program complexity. Counting frequency on discrete inputs is 1 kHz.

MPN
SR3B102BD