Skip to main content
Schneider Electric METSEEM3560A — Circuit Protection

Schneider Electric METSEEM3560A PowerLogic EM3560A Energy Me

MPNMETSEEM3560A
Active

Schneider Electric PowerLogic EM3560A, energy meter, Rogowski coil input 50...5000 A, accuracy Class 0.5S, 90...347 V, backlit LCD, DIN rail mount, dark grey.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

METSEEM3560A — Identification
ParameterValue
Product / component typeEnergy meter
Device short nameEM3560A
RangePowerLogic
Product rangePowerLogic EM3500
Device applicationSub billing Partial meter
METSEEM3560A — Electrical
ParameterValue
Rated operational voltage (Ue)90...347 V AC 50/60 Hz between phase and neutral UL 156...600 V AC 50/60 Hz between phases UL 90...300 V AC 50/60 Hz between phase and neutral CE 125...300 V DC
Pole configuration3P + N
Power consumption (VA)5 VA 347 V AC between phase and neutral) 5 VA 600 V AC between phases)
METSEEM3560A — Mechanical
ParameterValue
Mounting supportDIN rail
Mounting modeBy screws Clip-on
Width4.2 in (107 mm)
Height3.6 in (91 mm)
Depth2.3 in (59 mm)
9 mm pitches12
METSEEM3560A — Environmental
ParameterValue
Operating ambient temperature-22...158 °F (-30...70 °C)
Storage ambient temperature-40...185 °F (-40...85 °C)
METSEEM3560A — Approvals
ParameterValue
StandardsIEC 61010-1 UL 508 CSA C22.2 No 14-05

Product details

Mounts on DIN rail or directly by screws — the clip-on tab snaps onto standard 35 mm rail, and the 4.2 x 3.6 x 2.3 in (107 x 91 x 59 mm) footprint fits a typical sub-panel without crowding adjacent breakers or contactors. The dark grey housing carries IEC 61010-1, UL 508, and CSA C22.2 No 14-05 approvals, so it passes inspection in North American and European panels alike. One alarm output (red LED threshold reached, green flashing output signal) can drive a local beacon or a PLC digital input. The tamperproof settings are protected by an access code — useful when the meter sits in a shared electrical room where you don't want the tenant adjusting the demand interval.

Frequently asked questions

What accuracy class does the METSEEM3560A meet?

It meets Class 0.5S for both power and energy per IEC 62053-22 and ANSI C12.20, with power and energy accuracy of ±0.5 %.

What input current range does the METSEEM3560A support?

It accepts Rogowski coil input from 50 to 5000 A, with a measurement current range of 20 to 5000 A.

Where can I buy the METSEEM3560A?

The METSEEM3560A is sourced and quoted to order against an RFQ through independent distribution. Contact us for current pricing and availability.

What compliance standards does the METSEEM3560A meet?

It is certified to IEC 61010-1, UL 508, and CSA C22.2 No 14-05, covering safety requirements for electrical measurement and control equipment.

MPN
METSEEM3560A