Skip to main content

Schneider Electric C40F Miniature Breakers Series

17 variants · Schneider Electric

About the Schneider Electric C40F Miniature Breakers Series

The Schneider Electric C40F Miniature Breakers Series series groups 17 related part numbers, each listed with full specifications, a datasheet where available, and an RFQ option. The listed variants share a common connection surface bottom of Front, connection surface top of Front and control type of Toggle. Variants differ by application, main product or component type and mechanical life cycles, so you can match the exact application your application requires using the selection guide below.

Select a variant by

Application
Distribution · Motor protection
Main product or component type
Basic frame · Circuit breaker
Mechanical life cycles
5000 cycles · 15000 cycles · 15000 cycles conforming to IEC 60947-2
Width
140 mm · 185 mm
Electrical life cycles
1000 cycles at 1000 V In · 2000 cycles at 750 V In/2 1000 cycles at 750 V In · 12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Trip unit type
Electronic · Thermal-magnetic

Shared specifications

Connection surface bottom
Front
Connection surface top
Front
Control type
Toggle
Depth
110 mm
Height
255 mm
IP rating
IP40
Operating temperature
-25...70 °C
Pollution degree
class 3
Storage temperature
-50...85 °C
Temp operating max
70 °C
Temp operating min
-25 °C
Temp storage max
85 °C

Variant comparison

ParameterC40F3C40F31M320C40F32M320C40F3TM250DC40F3TM320DC40F3TM400
ApplicationDistributionMotor protectionMotor protectionDistributionDistributionDistribution
Main product or component typeBasic frameCircuit breakerCircuit breakerCircuit breakerCircuit breakerCircuit breaker
Mechanical life cycles15000 cycles conforming to IEC 60947-215000 cycles15000 cycles5000 cycles5000 cycles15000 cycles
Width140 mm140 mm140 mm140 mm140 mm140 mm
Electrical life cycles12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In2000 cycles at 750 V In/2 1000 cycles at 750 V In2000 cycles at 750 V In/2 1000 cycles at 750 V In12000 cycles at 440 V In/2 6000 cycles at 440 V In 6000 cycles at 690 V In/2 3000 cycles at 690 V In
Trip unit typeElectronicElectronicThermal-magneticThermal-magneticThermal-magnetic

Request a quote on any Schneider Electric C40F Miniature Breakers Series part number and we confirm price, availability and lead time per line — including end-of-life and allocation-constrained variants.

All variants