Found 46 results for “overload relay” (filtered) (46 products, 0 articles).
Schneider MGP0802L3N Powerpact 4 — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.
Schneider MGP0402L2N Powerpact 4 — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.
Schneider MGP0402L3N Powerpact 4 — now discontinued. Supplied from remaining channel stock; full specifications, lifecycle and same-series options are below.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0632L2N, 2-pole 1P+N, 63A, 25kA Icu at 415V AC, thermal-magnetic TM-D trip unit.
Schneider Electric PowerPacT 4, MCCB, 1P+N, 100A at 40°C, TM-D thermal-magnetic trip, 25kA Icu at 415V AC, BS EN 60947-2.
Schneider Electric PowerPacT 4 series, MGP0632L1N Molded Case Circuit Breaker, 1P+N, 63 A at 40 °C, 230 V AC, 25 kA Icu at 415 V AC, TM-D trip unit, thermal-magnetic LI protection.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0162L1N, 1P+N, 16 A, 415 V, 25 kA Icu, BS EN 60947-2, obsolete.
Schneider Electric PowerPacT 4, MGP1252L3N, Molded Case Circuit Breaker, 1P+N, 125A at 40°C, 230V AC, 25kA Icu at 415V AC, thermal-magnetic TM-D trip unit, toggle control, panel-mounted.
Schneider Electric PowerPacT 4, Molded Case Circuit Breaker, 1P+N, 125A, 230V AC, TM-D trip unit, BS EN 60947-2.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP1252L1N, 1P+N, 125A, 230 V AC, 25 kA Icu at 415 V AC, thermal-magnetic trip unit TM-D.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0802L2N, 1P+N, 80A at 40°C, 230V AC, 25kA Icu/Ics at 415V AC, TM-D thermal-magnetic trip unit, LI protection, BS EN 60947-2.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0802L1N, 1P+N, 80 A at 40 °C, 230 V AC, 25 kA Icu/Ics at 415 V, thermal-magnetic trip unit TM-D, BS EN 60947-2.
Schneider Electric PowerPacT 4, Molded Case Circuit Breaker, 1P+N, 30 A at 40 °C, 230 V AC, TM-D trip unit, backplate mount.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0252L2N, 1P+N, 25 A at 40 °C, 230 V AC, 25 kA Icu at 415 V AC, TM-D trip unit, LI protection.
Schneider Electric PowerPacT 4 molded case circuit breaker, MGP0162L2N, 1P+N, 16A, 25 kA Icu at 415 V AC, thermal-magnetic TM-D trip unit.
Schneider Electric PowerPacT 4, MGP0252L1N, Molded Case Circuit Breaker, 1P+N, 25A at 40°C, 230 V AC, TM-D trip unit, LI protection.
Schneider Electric PowerPacT 4, MGP0302L1N, molded case circuit breaker, 1P+N, 30A, 25 kA Icu at 415 V AC, thermal-magnetic TM-D trip unit, panel-mounted.
ABB 2CCS471001R0277 1-Pole MCB (DIN Rail), K tripping characteristic, 2 A rated current, 440 V rated insulation voltage, 10 kA Icn / 50 kA Icu, IP20, screw terminals.