Found 162 results for “three phase motor” (filtered) (60 products, 0 articles).
ABB PSTX37 soft starter, 1SFA898104R7000, 208-600 VAC, 50/60 Hz, auto phase sequence detection, ramp time 1-120 s, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profinet, DeviceNet, CANopen, Profibus, BACnet-IP/MSTP, built-in electronic overload, IP00 main terminals.
Schneider Electric Altistart 48 series, ATS48D62YS316 soft starter for asynchronous motor, 30 kW at 400 V standard duty, AC-53A utilisation category, 208...690 V supply, 50/60 Hz, Modbus RS485, CE.
Siemens SIRIUS 3RW4457-2BC44 soft starter, 1524 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass contact system, inside-delta circuit, screw fixing, 640 x 510 x 290 mm.
Siemens SIRIUS 3RW4456-2BC44 soft starter, 1351 A at 40 °C, 690 V insulation voltage, 50/60 Hz, integrated bypass, inside-delta capable, display for fault signal.
ABB, PSRC3, Soft Starters, 1SFA896203R7000, Soft start with voltage ramp, 208... 600 V AC, 50/60 Hz, Fixed setting ramp time, Screw Terminals, IP20, Operation -25... +60 °C.
Siemens 3RW5547-6HA16 soft starter, 200-690 V AC, 50/60 Hz, ATEX/IECEx certified, trip classes CLASS 10A/10E/20E/30E per IEC 60947-4-2, screw terminal, PROFIBUS/Modbus/EtherNet/IP, active production.
ABB PSTX37 series softstarter, order code 1SFA898204R7000, 208-690 V AC, 50/60 Hz, with auto phase sequence detection and built-in electronic overload.
ABB PSTX30 soft starter, 1SFA898103R7000, auto phase sequence detection, ramp time 1-120 s, 208-600 V AC, multi-protocol fieldbus.
ABB PSTX1050 soft starter, 1SFA898220R7000, auto phase sequence detection, 208-690 V AC, ramp time 1-120 s, multi-protocol communication.
ABB PSTX85 series soft starter, order code 1SFA898108R7000, 208-600 V AC, built-in electronic overload, auto phase sequence detection, multi-protocol fieldbus.
ABB PSTX1250 soft starter, order code 1SFA898221R7000, auto phase sequence detection, ramp time 1...120 s, multi-protocol fieldbus, 208...690 V AC.
ABB PSTX60 soft starter, 1SFA898206R7000, auto phase sequence detection, ramp time 1–120 s, 208–690 V AC, 50/60 Hz, multi-protocol communication.
ABB PSTX85 soft starter, 1SFA898208R7000, auto phase sequence detection, ramp time 1-120 s, 208-690 V AC, multi-protocol communication.
ABB, PSTX840 series, Soft Starter, 1SFA898119R7000, 208...600 V AC, 100...250 V AC control supply, 24 V DC control circuit, 1...120 s ramp time, auto phase sequence detection.
ABB PSTX142 soft starter, order code 1SFA898210R7000, 208…690 V AC, auto phase sequence detection, ramp time 1…120 s, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profinet.
ABB PSTX300 series soft starter, 1SFA898214R7000, auto phase sequence detection, 208...690 V AC, 50/60 Hz, 1...120 s ramp, multi-protocol fieldbus.
ABB PSTX250 soft starter, 1SFA898213R7000, auto phase sequence detection, 208-690 V AC, 50/60 Hz, 100-250 V AC control supply, Modbus/Ethernet/IP fieldbus.
ABB PSTX370 soft starter, 1SFA898215R7000, auto phase sequence detection, 208-690 V AC, 50/60 Hz, multi-protocol fieldbus.
ABB PSTX170 soft starter, 1SFA898211R7000, auto phase sequence detection, ramp time 1–120 s, multi-protocol communication (Modbus-RTU/TCP, Ethernet/IP, EtherCAT, DeviceNet, CANopen, Profibus, Profinet, BACnet), 208–690 V AC, 100–250 V AC control supply, 24 V DC control circuit.
ABB PSTX250 soft starter, order code 1SFA898113R7000, auto phase sequence detection, 208-600 V AC, 50/60 Hz, multi-protocol communication.
ABB, PSTX840 series, soft starter, 1SFA898219R7000, 208...690 V AC, 50/60 Hz, auto phase sequence detection, ramp 1...120 s, multi-protocol fieldbus.
ABB, PSTX Series, Soft Starter, 1SFA898217R7000, Auto phase sequence detection, 208...690 V AC, 200 HP at 200-208 V AC UL/CSA, ramp time 1...120 s, communication Modbus-RTU/TCP, Ethernet/IP, Profinet, BACnet.
ABB PSTX45 soft starter, 1SFA898105R7000, 208-600 V AC, built-in electronic overload, auto phase sequence detection, multi-protocol communication.
ABB PSTX105 soft starter, 1SFA898209R7000, auto phase sequence detection, 208-690 V AC, 50/60 Hz, Modbus-RTU/TCP, Ethernet/IP, EtherCAT, Profinet, 1-120 s ramp time.
PSTX1250-600-70 Softstarter - 1250 A - 208... 600 V AC
PSTX72-690-70 Softstarter - 72 A - 208... 690 V AC
ABB PSTX1050 soft starter, 1SFA898120R7000, 208-600 V AC, 400 HP at 200-208 V, built-in electronic overload, multi-protocol communication.
ABB PSRC37 soft starter, 1SFA896210R7000, voltage ramp function, fixed ramp time, 208-600 V AC, 100-240 V AC control supply, 24 V DC control circuit, 4xIe starting capacity for 6 s.
ABB PSR3 series soft starter, order code 1SFA896103R1100, voltage ramp function, 208–600 V AC operational voltage, 24 V AC/DC control supply, screw terminals.
ABB PSE25 soft starter, 1SFA897102R7000, soft start with torque control, 0...30 s ramp, Modbus-RTU, 4...20 mA analog outputs, 208...600 V AC, current lifecycle stage.
ABB PSRC6-600-70, 1SFA896204R7000, soft starter with voltage ramp, rated 208-600 V AC, control supply 100-240 V AC, IP20 main terminals.
ABB PSRC9 series soft starter, order code 1SFA896205R7000, voltage-ramp soft start, 208-600 V AC, 4xIe for 6 s, screw terminals, current lifecycle.
ABB, PSRC16 series, Soft start with voltage ramp, 1SFA896207R7000, 208-600 V AC, 4xIe for 6s starting capacity, IP20 screw terminals.
ABB, PSRC12 series, soft starter with voltage ramp, 1SFA896206R7000, 208...600 V AC, 4xIe starting capacity, 24 V DC control, IP20.
ABB PSRC25 soft starter, 1SFA896208R7000, soft start with voltage ramp, 208-600 V AC, 7.5 HP UL/CSA, 4x Ie for 6s starting capacity, IP20 terminals.
ABB PSRC30-600-70 soft starter, Function Soft start with voltage ramp, Rated Operational Voltage 208... 600 V AC, Starting Capacity 4xIe for 6s, lifecycle_stage current.
ABB PSE18, Soft start with torque control, 1SFA897101R7000, 208-600 V AC, 0-30 s ramp, Modbus-RTU, 4-20 mA analog outputs, screw terminals.
ABB PSE370 soft starter, 1SFA897115R7001, soft start with torque control, 208...600 V AC, Modbus-RTU, 0...30 s ramp, current production.
ABB PSE300 soft starter, order code 1SFA897114R7001, soft start with torque control, 208-600 V AC, Modbus-RTU, built-in electronic overload protection.
ABB, PSRC72 series, soft starter with voltage ramp, 1SFA896213R7000, 20 Hp at 200-208 V AC three-phase (UL/CSA), 100-240 V AC control supply, 24 V DC control circuit.
ABB PSRC105 soft starter, 1SFA896215R7000, soft start with voltage ramp, 208-600 V AC, 30 Hp UL/CSA, fixed ramp time, 100-240 V AC control supply, 24 V DC control circuit.
ABB PSE210 soft starter, 1SFA897112R7001, soft start with torque control, 208...600 V AC, 50/60 Hz, Modbus-RTU, 0...30 s ramp, built-in electronic overload protection.
ABB PSRC60 soft starter, 1SFA896212R7000, soft start with voltage ramp, 208-600 V AC, 100-240 V AC control supply, 24 V DC control circuit, 50/60 Hz, current production.
ABB PSRC85 soft starter, 1SFA896214R7000, soft start with voltage ramp, 208-600 V AC, 25 Hp at 200-208 V, 4x Ie for 6s, current production.
Siemens SIRIUS 3RW5144-1XC14 soft starter, 100 A minimum, 200-480 V, trip class 10A/10E/20E, screw fixing, 210 x 417 x 203 mm (WxHxD).
Siemens SIRIUS 3RW5135-1XC14 soft starter, 68 A minimum, 200-480 V rated, Trip Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 324 x 185 x 203 mm.
Siemens SIRIUS 3RW5148-1XC14 soft starter, 240 A minimum, 200-480 V rated, Class 10A/10E/20E, PROFIBUS, Modbus RTU, PROFINET, screw terminals, screw fixing.
Siemens 3RW5135-1XC14-0S soft starter, 68 A minimum, 200-480 V, Trip Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw terminals, 203x185x324 mm.
Siemens 3RW5148-1XC14-0S soft starter, 240 A minimum, 200-480 V rated voltage, Trip Class 10A/10E/20E, PROFIBUS, Modbus RTU, PROFINET, screw fixing, 417 x 210 x 203 mm.
Siemens 3RW5077-6AB05 soft starter, 240 A minimum, 200-600 V rated voltage, ATEX, IECEx, UL, CSA, CE, PROFIBUS, PROFINET, Modbus RTU/TCP, EtherNet/IP, 282 mm depth, 160 mm width, 230 mm height.
Siemens SIRIUS 3RW5235-2TC05 hybrid soft starter, 68 A minimum, 200-600 V rated, Trip Class 10A, PROFIBUS/Modbus/EtherNet/IP, screw fixing, 306×185×203 mm.
Siemens 3RW5056-2AB14 SIRIUS soft starter, 81 A minimum, 200-480 V rated voltage, ATEX/UKEX/IECEx certified, Class 10A/10E/20E trip, hybrid switching device, screw fixing.
Siemens SIRIUS 3RW5216-3AC05 soft starter, 14 A minimum, 200-600 V rated voltage, trip class CLASS 10A/10E/20E per IEC 60947-4-2, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing, 275 x 170 x 152 mm.
Siemens SIRIUS 3RW5214-1TC05 soft starter, 200-600 V control supply, Class 10A / 10E / 20E trip, PROFIBUS/Modbus/EtherNet/IP/PROFINET, UL/CSA/CE, current production.
Siemens 3RW5215-1TC15 soft starter, 200-600 V rated, 11.5 A minimum, CLASS 10A/10E/20E per IEC 60947-4-2, PROFIBUS, Modbus RTU/TCP, EtherNet/IP, PROFINET, screw fixing.
Siemens SIRIUS 3RW5056-2TB14 soft starter, 81 A minimum rated current, 200-480 V rated voltage, ATEX and IECEx certified, Trip Class 10A/10E/20E per IEC 60947-4-2, PROFIBUS and Modbus RTU/TCP.
Siemens SIRIUS 3RW5145-1XC14 soft starter, 135 A minimum, 200-480 V, trip class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw terminals, 417x210x203 mm.
Siemens SIRIUS 3RW5127-1XC14 soft starter, rated 40.5 A minimum at 200-480 V, Trip Class 10A/10E/20E, PROFIBUS/Modbus RTU/PROFINET, screw fixing, 203×185×321 mm.
Siemens 3RW5526-3HA14 soft starter, 200-480 V, ATEX/IECEx, Class 10A/10E/20E/30E, Modbus RTU/TCP, EtherNet/IP, PROFIBUS, 306 x 185 x 203 mm.